rsd_lib.resources.v2_1.chassis.thermal_zone
Module¶rsd_lib.resources.v2_1.chassis.thermal_zone.
FanCollectionField
(*args, **kwargs)¶Bases: sushy.resources.base.ListField
name
= <sushy.resources.base.Field object>¶The Power Supply name
rack_location
= <rsd_lib.resources.v2_1.common.rack_location.RackLocationField object>¶The Fan physical location
reading_rpm
= <sushy.resources.base.Field object>¶Fan RPM reading
status
= <rsd_lib.base.StatusField object>¶The Fan status
rsd_lib.resources.v2_1.chassis.thermal_zone.
TemperatureSensorCollectionField
(*args, **kwargs)¶Bases: sushy.resources.base.ListField
name
= <sushy.resources.base.Field object>¶The Power Supply name
physical_context
= <sushy.resources.base.Field object>¶Describes the area or device to which this temperature measurement applies: “Intake” - The intake point of the chassis “Exhaust” - The exhaust point of the chassis “Backplane” - A backplane within the chassis “PowerSupply” - A power supply “SystemBoard” - The system board (PCB) “ComputeBay” - Within a compute bay “PowerSupplyBay” - Within a power supply bay
reading_celsius
= <sushy.resources.base.Field object>¶Current value of the temperature sensor’s reading
status
= <rsd_lib.base.StatusField object>¶The temperature sensors status
rsd_lib.resources.v2_1.chassis.thermal_zone.
ThermalZone
(connector, path='', redfish_version=None, registries=None, reader=None)¶Bases: rsd_lib.base.ResourceBase
desired_speed_pwm
= <sushy.resources.base.Field object>¶The desired FAN speed in current ThermalZone present in PWM unit
desired_speed_rpm
= <sushy.resources.base.Field object>¶The desired FAN speed in current ThermalZone present in RPM unit
fans
= <rsd_lib.resources.v2_1.chassis.thermal_zone.FanCollectionField object>¶Details of the fans associated with this thermal zone
max_fans_supported
= <sushy.resources.base.Field object>¶Number of maximum fans that can be installed in a given Thermal Zone
number_of_fans_present
= <sushy.resources.base.Field object>¶The existing number of fans in current ThermalZone
presence
= <sushy.resources.base.Field object>¶Indicates the aggregated Power Supply Unit presence information Aggregated Power Supply Unit presence format: Length of string indicate total slot of Power Supply Units in PowerZone.
For each byte the string: “1” means present “0” means not present
rack_location
= <rsd_lib.resources.v2_1.common.rack_location.RackLocationField object>¶The ThermalZone physical location
status
= <rsd_lib.base.StatusField object>¶The ThermalZone status
temperatures
= <rsd_lib.resources.v2_1.chassis.thermal_zone.TemperatureSensorCollectionField object>¶Array of temperature sensors
volumetric_airflow
= <sushy.resources.base.Field object>¶Rack Level PTAS Telemetry - Volumetric airflow in current ThermalZone
rsd_lib.resources.v2_1.chassis.thermal_zone.
ThermalZoneCollection
(connector, path, redfish_version=None, registries=None)¶Except where otherwise noted, this document is licensed under Creative Commons Attribution 3.0 License. See all OpenStack Legal Documents.